Welcome to the official website of Lihong Safety Equipment Engineering (Shanghai) Co., Ltd.!
Position首頁(yè) > Home > Industrial Safety Products > Safety interlock switch > Magnetic induction switch
LMC3-50 series RFID safety door switch

1706678051308494.pngimage.png

With detection confidentiality (unique code can be provided)

?Strong anti-interference, safety and reliability.

?Safety level PLe can be achieved by using safe dual-channel output technology.

?Effectively prevent false positives or false negatives, or artificial abnormal triggers.

?Can be used with the safety door.


395181ccb7a771e30162f6415dc922a.png

Ordering information

86b9d0315b563dc534da6381bf695f3.png

Switch model

Specification

Output method

Encoding method

LMC3-50-40SNT/5M


4-core direct wiring with dual output
5M cable


NPN

Universal encoding

LMC3-50-40SN1/5M

Unique encoding

LMC3-50-40SPT/5M

4-core direct wiring with dual output
5M cable


PNP

Universal encoding

LMC3-50-40SP1/5M

Unique encoding

LMC3-50-60JNT/5M

6-core direct wiring with dual output and cascading 5M cable

NPN

Universal encoding

LMC3-50-60JN1/5M

Unique encoding

LMC3-50-60JPT/5M

6-core direct wiring with dual output and cascading 5M cable

PNP

Universal encoding

LMC3-50-60JP1/5M

Unique encoding

395181ccb7a771e30162f6415dc922a.png

Model Description


395181ccb7a771e30162f6415dc922a.png

Technical parameter

Safty standard

Mean Time to Dangerous Failure (MTTFd) (years)

ISO13849-11EC/EN60947-5-1IEC/EN60947-5-3

≥30 years

Safety classification

Class 4 switch according to IS0 13849-1/suitable for PLe/PL

Certification

CE

Horizontal working distance

Conduction, min:10mm

Vertical working distance

Conduction, min:8mm

Operating voltage

24V DC±15%

Operating current

150mA

Response time

60ms

The protection grades

IP65, IP67 (customized)

Operating frequency

lHZ

Working temperature

-10~+55℃

Relative humidity

5%~95%

Material

Flame-retardant thermoplastic


395181ccb7a771e30162f6415dc922a.png

Shape and installation dimensions

尺寸圖.pngLMC3-50.png


395181ccb7a771e30162f6415dc922a.png

Approach pattern of LMC3-50 switch

1706679390304986.png1706679459242220.png


395181ccb7a771e30162f6415dc922a.pngLMC3-50 switch induction distance


Misalignment deviation

breakover

disconnect

Alignment signal

Horizontal alignment

The deviation is within 4 mm in the X direction.Y direction induction 0~10mmY direction induction distance > 25mmLMC3-50.png
The deviation is > 5mm and < -5mm in the x direction.Not recommended

Vertical alignment

The deviation is within 4mm of soil in X direction.Z direction induction distance 0~8mmZ direction induction distance > 23mmLMC3-510.png
The deviation is > 5mm and < -5mm in the x direction.Not recommended


395181ccb7a771e30162f6415dc922a.png

Hookup

Two-way output with cascade connection diagram

serial number

Signal definition

colour

explain

1706680404188780.png

1

24V

palm

Power supply positive

2

0V

blue

Negative power supply

3

output1

black

Safety output 1

4

output2

white

Safety output 2

5

input1

green

Cascade input 1

6

input2

yellow

Cascade input 2


395181ccb7a771e30162f6415dc922a.pngLegend of connection between RFID switch and safety relay module (dual output)


接線圖.png



395181ccb7a771e30162f6415dc922a.png

RFID switch approach pattern

Led display

Signal state

State description

input

output

The red light is always on.

Yes/No.

break

No actuator or incomplete alignment (universal coding)

The red light is on for 1 second and then flashes twice (alternately).

Yes/No.

break

No actuator or incomplete alignment (unique code)

Red light flashing at 4Hz

effective

break

Output overload

Green light flashes at 1Hz.

be invalid

break

No input signal (dual output is not applicable)

The green light is always on

effective

through

Induction is normal

Alternate flashing of traffic lights

effective

break

Label is not registered.


Related Products
Download
PDF file download
Video file download
Previous

Contact us

400-881-6062

Lihong Safety Equipment Engineering (Shanghai) Co., Ltd.

E-Mail: info@lh-safety.com

Address: 581 Xiuchuan Road, Chuansha Town, Pudong New District, Shanghai

(Greenland East Coast International Plaza-Room A 313)

Copyright ? Lihong Safety Equipment Engineering (Shanghai) Co., Ltd.  ICP19034341-1  Technical Support: lanjujing

Online service

Online message

  • Click to refresh
  • 主站蜘蛛池模板: 漳州市| 邹平县| 瑞丽市| 阿坝| 喀喇| 宣汉县| 二连浩特市| 祁东县| 固原市| 山阳县| 泾川县| 南木林县| 民乐县| 横山县| 华坪县| 康定县| 稷山县| 塘沽区| 盐池县| 临安市| 麦盖提县| 当雄县| 湛江市| 缙云县| 涿鹿县| 繁峙县| 久治县| 铜梁县| 邵东县| 弥渡县| 菏泽市| 云阳县| 沙湾县| 沁阳市| 图片| 宜州市| 左权县| 连州市| 乐东| 绥宁县| 云林县|